FUNCTIONS & FEATURES
Main Characteristics
- Dynamic range up to 125dB; accurate measurement on high rejection ratio devices
- 75Ω test port impedance option of 3656A for cable TV components measurement
- 3656A/B/D provide 4-port option which can accomplish all 16 S parameters test of 4-port net by a single connection
- Note: For 4-port option of 3656A/B, it’s external device 2813A
- Ultra-low trace noise which provide higher test accuracy
- Up to 64 independent measuring channels that can implement complex testing schemes rapidly
- Powerful data analysis functions, such as ripple test, bandwidth test and limit test, convenient for user to judge the conformity and
- improves the test efficiency
- Time domain analysis function as the standard configuration
- Fixture simulator can simulate various R&D situations to rapidly get the real-time test results
- LAN and GPIB interface, capable of remote control and system interconnection, 4 USB interfaces
Large dynamic range
With dynamic range up to 125dB (IFBW=10Hz), 3656A/B/D is capable of accurate measurement on devices with high rejection ratio.
Ultra -low trace noise
Trace noise of 3656A/B/D is ultra-low, which minimizes measurement error.
Time-domain analysis function
The analyzer can conduct time-domain measurement on DUT via time-domain software so as to comprehensively test the performance indicators of DUT, such as cable fault location and length measurement.
Powerful data analysis function
It has analysis functions such as limit test, ripple test and bandwidth test, filter automatic statistics etc., which can clearly test the loss, ripple and rejection and help for conduct hopping filter debugging.
TYPICAL APPLICATIONS
Production test of mobile communication products
The frequency range of 3656A/B/D vector network analyzer can meet the demand of production test on mobile communication products. It has advantages of high sweep speed, wide dynamic range and compact size which is very suitable for the test of mass production in factories. 3656A/B/D can be applied to the test of RF components such as filter, amplifier, antenna and cables. The 75Ω test assembly of 3656A is also available for performance test of CATV devices.
Test of passive multi-port device and balanced device
3656A/B/D VNA provide 4-port test function . It can test the whole 16 S parameters of 4-port network via one single connection, thus is very suitable for the mass production test of multi-port devices in factories. It has balanced parameter test function: after the full 3-port or full 4-port calibration using 3 or 4 test ports, choose the corresponding operation mode (single port-balanced network, single port-single port-balanced network, balanced-balanced network), then you can gain the mixed S-parameters of balanced devices.
Notes: For 4-port option of 3656A/B, it’s external device 2813A
3656A/B Technical Specifications
Parameters | 3656A | 3656B |
Frequency range | 100kHz ~ 3GHz | 100kHz ~ 8.5GHz |
Frequency resolution | 1Hz | 1Hz |
Frequency accuracy | ±5×10-6(23℃±3℃) | ±5×10-6(23℃±3℃) |
Output power setting range | -45dBm~+10dBm | -55dBm~+10dBm |
System dynamic range
|
(10Hz) (3kHz)
100kHz~1MHz 90dB 60dB 1MHz~10MHz 110 dB 80 dB 10MHz~3GHz 125dB 95dB |
(10Hz) (3kHz)
100kHz~20MHz 110dB 80dB 20MHz~3GHz 125 dB 95 dB 3GHz~6GHz 123dB 93dB 6GHz~8.5GHz 118dB 88dB |
Reflection track | 100kHz~10MHz ±0.030dB
10MHz~3GHz ±0.020dB |
100kHz~3GHz ±0.030dB
3GHz~6GHz ±0.040dB 6GHz~8.5GHz ±0.050dB |
Transmission track | 100kHz~10MHz ±0.030dB
10MHz~3GHz ±0.020dB |
100kHz~3GHz ±0.030dB
3GHz~6GHz ±0.040dB 6GHz~8.5GHz ±0.050dB |
Effective directivity | 100kHz~10MHz 49 dB
10MHz~3GHz 46 dB 100kHz~10MHz 49dB (option H01) 10MHz~3GHz 46dB (option H01) |
100kHz~3GHz 46dB
3GHz~6GHz 40dB 6GHz~8.5GHz 38dB |
Effective source match | 100kHz~10MHz 44dB
10MHz~3GHz 40dB 100kHz~10MHz 43dB (option H01) 10MHz~3GHz 21dB (option H01) |
100kHz~3GHz 36dB
3GHz~6GHz 35dB 6GHz~8.5GHz 33dB
|
Effective load match | 100kHz~10MHz 49 dB
10MHz~3GHz 46 dB 100kHz~10MHz 48dB (option H01) 10MHz~3GHz 41dB (option H01) |
100kHz~3GHz 44dB
3GHz~6GHz 40dB 6GHz~8.5GHz 36dB
|
Test points | 1 to 16001 | |
IF bandwidth | Min. 1Hz;Max. 5MHz,in 1,2,3,5,7 step | |
Port connector type | Type-N (female) 50 ohm system impedance
Type-N (female) 75 ohm system impedance(3656-H01) |
|
Number of test ports | 2 | |
Number of test receivers | 4 | |
Reference level amplitude setting | Setting range: ±500dB
Setting resolution: 0.001dB |
|
Reference phase setting | Setting range: ±500°
Setting resolution: 0.01° |
|
Time-base reference output | Output frequency: 10MHz
Output level: +10dBm±4dB |
|
Digital interface | GPIB, USB, Ethernet interface and VGA display interface | |
Operation system | Windows XP | |
Display | 10.4-inch high brightness LCD | |
Test domain | Frequency domain, Time domain | |
Dimensions | 435×233×348 (W×H×D) (including foot pad, foot, lateral stripping, input and output port) | |
Power consumption | 150W | |
Power supply | 50Hz single phase 220V or 50Hz/60Hz single phase 110V AC | |
Weight | 16kg |
3656D Technical Specifications:
Parameters | 3656D | ||
Frequency range | 300kHz ~ 20GHz | ||
Frequency resolution | 1Hz | ||
Frequency accuracy | ±1×10-6(23℃±3℃) | ||
System dynamic range IF bandwidth:10Hz |
Frequency range | 2-port | 4-port |
300kHz~100MHz | 95dB | 90 dB | |
100MHz~1GHz | 110dB | 100 dB | |
1GHz~6GHz | 120dB | 115 dB | |
6GHz~8GHz | 117dB | 110 dB | |
8GHz~10GHz | 115dB | 105 dB | |
10GHz~15GHz | 110dB | 100 dB | |
15GHz~20GHz | 100dB | 90 dB | |
Reflection track | 300kHz~10MHz ±0.030dB
10MHz~3GHz ±0.040dB 3GHz~20GHz ±0.050dB |
||
Transmission track | 300kHz~10MHz ±0.030dB
10MHz~3GHz ±0.040dB 3GHz~6GHz ±0.100dB 6GHz~20GHz ±0.150dB |
||
Effective directivity | 300kHz~10MHz 46dB
10MHz~3GHz 42dB 3GHz~6GHz 38dB 6GHz~20GHz 36dB |
||
Effective source match | 300kHz~10MHz 37dB
10MHz~3GHz 37dB 3GHz~6GHz 31dB 6GHz~20GHz 28dB |
||
Effective load match | 300kHz~10MHz 44dB
10MHz~3GHz 42dB 3GHz~6GHz 38dB 6GHz~20GHz 36dB |
||
Test points | 1 to 16001 | ||
IF bandwidth | Min. 1Hz;Max. 5MHz,in 1,2,3,5,7 step | ||
Port connector type | 3.5mm (male) 50 ohm system impedance | ||
Number of test ports | 2/4 | ||
Number of test receivers | 2/4 | ||
Reference level amplitude setting | Setting range:±500dB
Setting resolution:0.001dB |
||
Reference phase setting | Setting range:±500°
Setting resolution:0.01° |
||
Time-base reference output | Output frequency:10MHz Output level:+10dBm±4dB | ||
Digital interface | GPIB, USB, Ethernet interface and VGA display interface | ||
Operation system | Windows XP | ||
Display | 10.4-inch high brightness LCD | ||
Test domain | Frequency domain, Time domain | ||
Dimensions | 436×236.5×410 (W×H×D) (including foot pad, foot, lateral stripping, input and output port) | ||
Power consumption | 150W | ||
Power supply | 50Hz single phase 220V or 50Hz/60Hz single phase 110V AC | ||
Weight | 18kg |